2P 4P 6 мА Постоянный ток Тип B EV автоматический выключатель остаточного тока RCCB RCD для точки

Сохранить в закладки 60724367090:


Цена:*

Количество:

  • В избранное

Описание и отзывы

Характеристики


 


 


KEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging point


 


KEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging pointKEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging point


 


1. Description of EV RCD
The Type EV RCCB has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of IEC62955. This provides a lower cost option to the Type B RCD, and has been designed specifically for use in Mode 3 and Mode 4 EV charging applications.
2. Main Features
1).Residual Current 6mA DC / 10mA AC or 6mA DC / 30mA AC
2).Operates from a 230V AC single phase supply (2 Pole) or 400V AC phase to phase (4 Pole)
3).For use with 2 or 3 phase loads rated up to 63A
4).Complies with the international standard of electric vehicle charging mode 3 (IEC62955)
5).3000A Surge Current Withstand
6).ROHS compliant


2. Main specification of residual current circuit breaker


 






























































































































Technical Date DGL2-63EV
Number of poles2P/4P
Residual current typeA
Rated current(AC)25A/40A/63A
Rated residual current IΔn0.03A
DC tripping threshold6mA
Min. operating voltage range of test circuit 150V
Max. operating voltage range of test circuit 250V
Auxiliary device(6mA DC detection)
Operating voltage of additional device85V-265V
Internal consumption of additional device1.7W
Load circuit
Specification Load disconnect contact
Min. contact opening4mm
Rated voltage(AC)230V, 400V
Rated current(AC)25A/40A/63A
Rated short circuit current 10kA
Surge current strength3kA
Max. total rated switchign capacity500A
rated insulation voltage 400V
Rated impulse withstand voltage4kV
Reted frequency50Hz
Current heat loss current path1.3W
Thermal backup-fuse OCPD40A
Short circuit backup-fuse SCPD100A
Back-up fuse typegG
General date
Max. operating altitude aabove MSL2000M
Mechanical endurancemin. 5000 cycles
Electrical endurancemin. 2000 cycles
Ambient temperature   -25°C up to +40°C

3. Diagram of RCCB


KEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging point


KEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging pointKEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging pointKEMA certified 4 pole type A 6mA DC EV RCD RCCB circuit breaker for charging point


 


 


1. Introduction of CHT Electric:


1.) Export experience more than 20 years.


2.)One of the largest factories specializing in circuit breaker in China. 


3.) We have our own lab to test flame resistance/ electric lifetime/temperature rise/breaking capacity/aging test, etc.


2. Circuit breaker Advantages:


1.)Small size and high breaking capacity 


2. )Competitive price, good reputation and prompt delivery time.


3.)Strict quality control ensure our excellent quality.
3. Our Service:  
1.) Well-trained salesman will reply inquiry with 8 hours 
2.) 5 years warranty 
4. Delivery time:       
10-15days after payment/deposit


 


 


 


 


 


Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам