Radiography of the mouth and associated structures can initially be very frustrating. However, once the
techniques are mastered, it is possible to produce high quality diagnostic radiographs consistently.
Dental radiography is consistently under-utilised in veterinary practice. In many procedures, diagnostic
radiographs are essential for the production of a treatment plan and treatment may be contraindicated without them
2.Kodak Dental X Ray Film Features
1. Number 1 quality in dental film industry.
2. Convenient: Could be wash by manual or processor machine and develop in light room.
3. CE ISO certificate, more reliable.
4. High Definition: The image is perfect definition and excellent resolution.
5. Comfortable: Soft plastic packing and thinner film, more comfortable to customer
6. Factory price
3. Package
100PCS/BOX;
80boxes/carton;
Carton size:0.32m×0.29m×0.44m
GW:15kgs/carton;
4. Instruction
How to Wash Dental Film in Light room
( i ) Light room Develop Condition and Method
1. Take dental film by normal procedure.
2. Extracted 3-5ml monobath with syringe, inject from the upper right corner into the dental film bag.
3. Press on the pinhole, shake or knead the dental bag property to coat the monobath on the film evenly, tear off film bag after 60-90s, and rinse off. (Note: Do not use your fingers to wipe the film’s surface in case of scratched.)
4. Dry the film off for inspection and diagnosis.
( ii ) Attentions
1. There is a convex point on the horns of dental film bag, used to judge the left
or right teeth. And the convex point side indicates the side faced radiation source.
2. The temperature of using monobath is good to set as 22℃, higher temperature makes the image too black and formed fog easily, lower makes the image subdued. Users can adjust the temperature according to the situation until clear.
3. Should be careful to inject liquor with a syringe, avoid transpierce the dental film bag to cause leakage.
4. Need to use the assorted Yes!Star monobath; the monobath should be sealed after use.
5.
Instructions (Problems & Reasons)
Problem: image too deep:
Reasons:
1: The development time is too long;
2: Washing liquid temperature is too high.
Problem: image too shallow:
Reasons:
1: The washing time is too short;
2: Washing liquid temperature is too low;
3: The liquid uses too long.
Main factors of dental film imaging quality
1. Right usage of X-ray and exposure;
2. Contact of film and teeth. (Affect clarity);
3. Quality & temperature of developer and fixer liquid.
Please feel free to tell us if any problems during usage, we'd love support you to solve the problems asap.