632.600 fast acting 6.3x32mm Fuse 600V 400ma 600ma 10a 12a multimeter fuse

Class of Operation: fast acting
Ratings:
Volts: 600V;
Amps: 400ma 600ma 10a 12a;
IR: 10kA@1000Vdc;
Standards / Approvals for Reference:
* Standard: UL 248-1;
* Agency File Number: JDYX2 E365879
Features & benefits:
* Fast acting, high breaking capacity;
* 6 x 32mm physical size;
* Ceramic tube, Silver plated copper cap;
* Lead free and Halogen free material;
* Normal operating conditions: - 5°C ~40°C;
* Permissible conditions of use: - 40°C~125°C;


  • Size introduction and size picture





  • * Electrical Characteristics



Item
Rated Current
Interrupting Capacity
Rated Voltage
Part No.
Typical Pre-arcing I²t(A²s)
1
200mA









10kA















600Vac
600Vdc
632.600.0.2
0.0036
2
250mA
632.600.0.25
0.004
3
400mA
632.600.0.4
0.059
4
500mA
632.600.0.5
0.085
5
600mA
632.600.0.6
0.120
6
800mA
632.600.0.8
0.175
7
1A
632.600.1
0.550
8
1.25A
632.600.1.25
1.350
9
1.6A
632.600.1.6
2.000
10
2A
632.600.2
2.600
11
2.5A
632.600.2.5
4.000
12
3A
632.600.3
4.800
13
4A
632.600.4
9.500
14
5A
632.600.5
27.000
15
6A
632.600.6
47.000
16
6.3A
632.600.6.3
50.000
17
8A
632.600.8
72.000
18
10A
632.600.10
105.00
19
12A
632.600.12
148.00
20
15A
632.600.15
220.00
21
16A
632.600.16
245.00
22
20A
632.600.20
400.00
23
25A
632.600.25
610.00
24
30A
632.600.30
1150.00


  • Time-Current Curve





Structure

Ceramic Tube:
* No breakage and cracks
Verification 1: Fix the end caps on both sides, apply 30N pressure at the center of the ceramic tube, and the ceramic tube shall not break.

End caps:
* The end cap shall be welded/riveted firmly, and the end cap shall not fall off without the elements damage.
Verification 1: soaking in 15-35°C water for more than 24hrs, then apply a pull force of 7N is evenly to both caps for 60s.
* The end caps should not fall off.
Verification 2: Fix the one of caps, apply 7N tension along the horizontal axis on the other cap , and the caps on both sides
shall not be loose and the body shall not be broken.
Verification 3: Fix the one of caps, apply 50N torque to twist the other cap in the clockwise and counter-clockwise direction, and the caps on both sides should not be loose and the body should not be broken.

Electrical Characteristics
* All the test conditions were carried out at 23±5°During this period, the variation of lab temperature should not exceed ±5°C.
* Load capacity test: when the fuse is tested at 100% rated current, the circuit shall not be disconnected, the fuse shall not be electrically fused, and the body shall not be broken within 4 hours.
* Temperature rise test: The fuse is tested at 100% rated current, when the fuse reaches heat balance, temperature rise of fuse surface and the caps must be no more than 130°C.
*Note: Temperature appreciation is constant fuse surface temperature minus current room temperature (ambient temperature).
* Current characteristics: When the fuse passes at the current specified below, the fuse time must meet the requirements of the table. The tube body should not be broken and the end caps should not fall off after fuse.



Current
1.0In
2.0In
2.5In
3.0In
200mA-800mA
4 Hour Min
120s Max
60s Max
15s Max
1A-12A
4 Hour Min
120s Max
30s Max
5s Max


Product Description




Cartridge uses with fuse clips
dia. 6mm x length 32mm
Fuses with pig-tails
Vacuum packaging,150*250mm,
200pcs per bag


Packing Instruction


Product Name: Suqare Body Fuse Links     Model: EVS4081~4088 ESH4454~4463
Fuse Links
Model
Packing Material
Size
Remarks


Vacuum Bag
150*250mm
200pcs per Box


Outer Carton
240*170*115mm
1000pcs per Carton






Certificate


Management System
IATF16949:2016, ISO/TS22163:2017, AS/EN9100:2018, ISO 9001:2015, ISO14001:2015, OHSAS1800






Lab Capacity
Electrical Performance Test
* Breaking Capacity Test
* Temperature Rise/Power Consumption Testing
* Overload Capacity Test
* Agree to Fuse, Agree Not to Fuse Test (IEC 60269, GB13539)
* Fuse Current Pulse Cycle Fatigue Test
Ambient Test
* Vibration Test (JASO-D622, GBT31467.3)
* Hot and Cold Impact Test (MIL-STD-202G)
* Temperature and Humidity Cycle Steam and Aging Test(GB/T2423)
* Salt Spray Test
* Horizontal and Vertical Combustion Test
* Glow Wire Test



CNAS CERTIFICATE
Registration No. CNAS L14234






Related Products




Company Introduction


Year Founded:
2008
Employees:
200

Area:
12,000 sq. meters

Address:
Songshan Lake Hi-tech Industrial Park, Dongguan City, Guangdong Province, China

Production Capability:
Display: 1,500 sq. meters Bonding: 5,500 sq. meters

Capabilities:
Electronic Fuse: SMT/Ceramic/Glass/Auto Fuse/Hi-current Fuse/ Micro Fuse
Power Fuse: Electric Vehicle/Train/Energy Storage/Hi-Voltage Fuse
45 Technical Patents

Quality Assurance:
TUV, UL, VDE, CSA, PSE, DIN, CCC, CQC Certified
CNAS Certified Lab
IATF16949: 2016
ISO/TS22163: 2017
AS/EN9100: 2018
ISO9001: 2015
ISO14001: 2015
OHSAS18000





Packing&Shipping




FAQ


Request For FUSE Suggestion
Don't know how to choose the correct fuses, pleaase fill out the table, so we can give you the best choice.


DATE
Customer
Project
Item
Value
Unit
Remarks
系统额定电压
Rated Voltage of System
Vdc
系统最大可持续电压
Max continuable Voltage of System
Vdc
时间常数(L/R)
Time Constant
ms
正常工作通过熔断器的电流
Fuse working current
A
最大可持续电流
Max continuable Current
A
快充最大电流
Fast charge maximum current
最大电流持续时间Duration of Max Current
sec
充电持续时间
Charging duration
峰值电流
Peak current
A
加速峰值电流
Peak acceleration current
峰值电流持续时间
Duration of Peak current
sec
加速时间
Acceleration time
熔断器所处环境温度Ambient Temperature of FUSE
有无强制风冷散热
Reinforced air-cooling heat disspation.
m/s
负载循环周期及波形Loading cycle time and waveform
最大短路电流值
Max short-circuit current
kA
最小短路电流值Minimum short-circuit current
kA
连接熔断器导线截面积
CSA of wire to connect fuse
mm2
有无保护器件配合及要求
Other protective device
熔断器安装位置Installation position of FUSE
系统故障电流源
Source of failure current
系统电源频率
Supply Frequency of system
Hz