Specification | *Rack-mounted 6kVA UPS customized ; *9Ah Battery pack customized, *Total backup time is 10-15 min; *Rack-mounted distribution module customized (Including C-level lightning protection, power monitoring) *PDU customized; *4.2KW Rack-mounted precision air conditioning customized (including outdoor unit) *AU Monitoring host and monitoring software | ||||||
Difference | Gcabling Micro Data Center | Traditional Small Data Center |
Computer Room | No need, fully enclosed with low noise, can be installed directly in the corner of office. Single cabinet occupies an area of 0.7-1.0㎡ | Need, occupying an area of about 10-20㎡ |
Decoration | No need | Need |
Operating Cost | Fully enclosed microenvironment, low energy consumption, with a PUE level around 1.5 | Air conditioning cools the entire room, resulting in high electricity costs, with an overall energy efficiency level between 2.0 and 3.0 |
Management and Maintenance | One-stop service, with IT personnel available on a part-time basis | Multi vendor procurement, unclear responsibility interface, requiring maintenance and management by multiple professionals |
Installation | Overall design, plug and play | UPS、 Air conditioners and cabinets are independently purchased and installed |
Construction Period | 1-2 days | 3-4 weeks |
Aesthetics | Appearance of the devices is coordinated and unified | Poor consistency in appearance between devices |
Cleanliness | Fully enclosed environment, cleanliness comparable to cloud computing rooms | Dependent on environmental conditions, long-term operation can easily accumulate dust, leading to device restart and downtime |
Noise | Noise level of 55dB (A), with minimal impact on the environment | Noise level is 65-70dB (A), requires sound insulation treatment |
UPS | Placed inside a sealed cabinet, with precision air conditioning to ensure operation | Independent UPS+battery cabinet, dependent on room temperature and cleanliness |
PDU | Equipped with SPD, well-known brand switches, and intelligent monitoring of power status | Wall mounted installation, no guarantee of air switch brand, no monitoring, no SPD |
Air Conditioner | Specialized precision air conditioning, 7×24 hour operation | Civil air conditioning does not match the needs of server operation, resulting in a high failure rate |
Monitoring | Complete monitoring (temperature, humidity, smoke, water leakage, video, UPS, air conditioning, electricity, energy consumption, email and SMS alerts), constantly monitoring the operating status | No monitoring or simple monitoring |