Паровой спрей стерилизатор реторт паровой реторт

Share on (554284436):


Price:

Quantity:


Product Overview

Description


 


Batch Sterilizers Steam / Water Spray sterilizer retort steam retort sterilizer autoclave


 


FEATURES


• Excellent temperature distribution


• Continuous process water


recirculation


• Powerful steam and waterspray


heating


• Efficient cooling


• Top spray for cans or glass jars


• Side spray for trays or pouches


• Continuous water level control and flow monitoring


• Programmable air-overpressure control


• Steam and water consumption minimal


 


 


 WATERSPRAY SYSTEM WORKING PRINCIPLE


 


1.  WATER FILLING


 


 


 


Prior to the start of the process, the retort is filled with a small volume of


process water (approx. 27 gallons/basket) such that the water level is below


the bottom of the baskets.  This water can be used for successive cycles if


desired, as it is sterilized with each cycle.


 


2.  HEATING


 


Once the cycle is begins, the steam valve opens and the circulation pump is


switched on.  The mixture of steam and water spraying from the top and the


sides of the retort vessel creates highly turbulent convection currents that


rapidly homogenizes the temperature at every point in the retort and  


between the containers.


 


3.  STERILIZATION


 


Once the programmed sterilization temperature has been reached, it is held


for the programmed time within +/- 1º F.  Similarly, the pressure is kept


within +/-1 psi by adding and venting compressed air as needed.


 


4.  COOLING


the end of the sterilization step, the retort switches into cooling mode.  As


the process water continues to be circulated through the system, a portion of


it is diverted through one side of a plate heat exchanger.  At the same time,


cold water passes through the other side of the plate heat exchanger.  This


results in the process water inside the retort chamber being cooled in a


controlled fashion.


 


5.  END OF CYCLE


 


Once the retort is cooled to the programmed temperature setpoint, the cold


water inlet valve on the heat exchanger closes and the pressure inside the


retort is automatically relieved.  The water level is lowered from the


maximum down to the medium level.  The door is equipped with a safety


locking device which prevents the opening of the door in the case of residual


pressure or high water level.


 