Peakmeter PM2108A 4000 Counts Ac Dc Current bar graph display Clamp Meter , Frequency Measurement Earth Leakage Clamp Meter
| SPECIFICATIONS | RANGE | ACCURACY |
| DC Voltage | 400mV/4V/40V/400V | ±(0.8%+3) |
| 600V | ±(1.0%+5) | |
| AC Voltage | 4V/40V/400V/600v | ±(1.0%+5) |
| AC Current | 40A/400A | ±(3.0%+10) |
| DC Current | 40A/400A | ±(3.0%+10) |
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ | ±(0.8%+3) |
| 40MΩ | ±(1.2%+3) | |
| Capacitance | 40nF/400nF/4μF/40μF/400μF/4000μF | ±(4.0%+5) |
| Frequency | 10Hz~10MHz | ±(0.5%+2) |
| Duty cylce | 0.1%~99.9% | ±3.0% |
| FEATURE | ||
| Auto and manual range | 4000 Counts | |
| Inrush current | √ | |
| Data hold | √ | |
| Work light | √ | |
| Diode test | √ | |
| Max/Min | √ | |
| Continuity | √ | |
| Back light | √ | |
| GENERAL | ||
| Power Supply | 3×1.5VAAA Battery | |
| Weight | Approx.245g | |
| Size | 280mm×78mm×35mm | |
| Jaw Size | φ26mm | |
| Safety Rating | EN61010-1,EN61010-2-032, EN61326,CAT.Ⅲ 600V | |