Soft Starter Introduction
The Delixi Soft Starter is a motor control equipment featuring soft start, soft parking, light-loading and energy-saving as well as multi-functional protection. The soft starter enables smooth and impact-less start during the whole start process, and the parameters such as current limit and start time can be adjusted according to the characteristics of the motor load. It can be divided into two categories: the Device-type Soft Starter and the Comprehensive-protection Soft Starter.
Applications
The soft starter can be applied to motors in crushers, compressors, transmission, pumps and air blowers
Product Characteristics
1. A Variety of Start Modes: Current limit soft start, ramp voltage soft start, ramp
voltage + current limit soft start.
2. Highly Reliable: A high-performance microprocessor performs digital processing
of the signals in the control system.
3. Strong Anti-interference Capability: Easy-tuning, optoelectronic-isolato r-based
signal transmission in the processing unit, di fferent anti-noise levels.
4. Optimum Structure: Unique compact structure, double-layer shell consisting of
plastic upper layer and metal lower layer to meet the aesthetic and durability
requirements.
5. Motor Protection: Multi-functional protection (e.g. in case of over-current,
input/output default phase, SCR short-circuit and overheat).
6. Easy Maintenance: Four-digit signal monitoring system to monitor the operation
of the system equipments in 24 hours and to offer quick fault diagnosis.
Technical Specification
Operation | Run control methods | Keyboard / External Terminal / RS485 Communication | |||
Start Mode | Current Limiting / Voltage / Heavy-load | ||||
Start & Stop Time | Can be digitally set. | ||||
Start Delay Time | Can be digitally set. | ||||
Emergency Stop | Output of the soft starter is interrupted. | ||||
Current Limit | The start current is below this value when the starter is run in the current limiting and heavy-load modes. | ||||
Initial Voltage | The initial voltage can be digitally set in the voltage mode. | ||||
Light-load Control | Can be used to check for accidents such as released belt buckle. | ||||
Restartability | Can be automatically restarted after it stops due to fault. | ||||
Fault Output | Contact Output — AC 250V 5A, DC 30V 5A | ||||
Multi-functional Relay Output | Start Delay, Start, Run, Stop, Complete Stop and Restart | ||||
Analogue Output | 0~20mA / 4~20mA Optional | ||||
Protection | Soft Starter Protection | Over-current, Over-load, Over-heat, Three Phases Imbalance, Open Phase, Light-load, External Fault | |||
Soft Starter Alarm | Emergency Stop, Light-load, Restart | ||||
Display |
Keyboard | Operation Information | Ready, Start Delay, Start Process, Run, Stop, Fault Alarm | ||
Parameter Protection | Parameters set as protected can not be modified. | ||||
Working Conditions | Usage Type | AC-53b | |||
Rated Insulation Voltage | 660V | Rated Impact Withstand Voltage | 4kV | ||
Operation Frequency | ≤ 12/hour | ||||
Protection Grade | CDRA011T4~CDRA055T4: IP20 CDRA075T4~CDRA600T4: IP00 | ||||
Rated Conditional Short-circuit Current | CDRA055T4: 6kA; CDRA160T4: 12kA | ||||
CDRA320T4: 20kA; CDRA600T4: 48kA | |||||
Environment | Ambient temperature | -10℃ ~ 40℃ | |||
Storage temperature | -20℃ ~ 65℃ | ||||
Ambient humidity | 90% RH in Max. (no dewing) | ||||
Height/vibration | Below 1,000 m, below 5.9m/sec² (=0.6g) | ||||
Application position | No corrosive gas, inflammable gas, oil mist, dust and others | ||||
Cooling | Natural air cooling |
CDRA Softer Starter Model Selection