Сохранить в закладки 1601074329703:
Specification
INPUT DATA | ||
Recommended Max PV Power (Wp) | 700 x 4 | |
Max DC Open Circuit Voltage (Vdc) | 62 | |
Max DC Input Current (Adc) | 18 x 4 | |
MPPT Tracking Accuracy | 99.9% | |
MPPT Tracking Range (Vdc) | 20-60 | |
Isc PV (absolute maximum) (Adc) | 25 x 4 |
OUTPUT (AC) | ||||||
Maximum Inverter Backfeed Current to the Array (Adc) | 0 | |||||
Rated AC Output Power (Wp) | 2000 | |||||
Nominal Power Grid Voltage (Vac) | 220 | 240 | 208 | |||
Allowable Power Grid Voltage (Vac) | 180-275* | 180-275* | 180-275* | |||
Allowable Power Grid Frequency (Hz) | 50/45-55 | 60/55-65 | 60/55-65 | |||
THD | <3% (at rated power) | |||||
Power Factor (cos phi, fixed) | >0.99(at rated power) | |||||
Rated Output Current (Aac) | 9.09 | 8.33 | 9.62 | |||
Current (inrush)(Peak and Duration) | 24A, 15us | |||||
Nominal Frequency (Hz) | 50 | 60 | 50 | |||
Maximum Output Fault Current (Aac) | 18.0A peak | |||||
Maximum Output Overcurrent Protection (Aac) | 18 | |||||
Maximum Number of Units Per Branch (10AWG) (All NEC adjustment factors have been considered) | 3 | 3 | 3 |
SYSTEM EFFICIENCY | ||
CEC peak Efficiency | 97.20% | |
Night Time Tare Loss (Wp) | 0.11 |
PROTECTION FUNCTIONS | ||||
Over/Under Voltage Protection | Yes | |||
Over/Under Frequency Protection | Yes | |||
Anti-Islanding Protection | Yes | |||
Over Current Protection | Yes | |||
Reverse DC Polarity Protection | Yes | |||
Overload Protection | Yes | |||
Protection Degree | NEMA-6 / IP-66 / IP-67 | |||
Ambient Temperature | -40°F to +149°F (-40°C to +65°C) | |||
Operating Temperature | -40°F to +185°F (-40°C to +85°C) | |||
Display | LED LIGHT | |||
Comunications(Wifi) | Frequency: 2.4 Ghz Standards: IEEE 802.11/b/g/n | |||
Dimension (W-H-D) | 11.81”x9.18”x1.50” (300x233x38 mm) | |||
Weight | 11.76 Ibs. (5.33 kg) | |||
Environment Category | Indoor and outdoor | |||
Wet Location | Suitable | |||
Pollution Degree | PD 3 | |||
Overvoltage Category | II(PV), III (AC MAINS) | |||
Product Safety Compliance | IEC/EN 62109-1 IEC/EN 62109-2 | California Rule 21certidied Ul1741 CSAC22.2 No.107.1 | ||
Grid Code Compliance* (Refer to the label for the detailed grid code compliance) | VDE-AR-N 4105*VDEV0126-1-1/A1G83/2,CEI 021AS4777.2&AS4777.3.EN50438ErzeugerTyp A | IEEE 1547-2018 |
By Express | DHL, TNT, UPS, FEDEX , Door to Door Service |
By Air | Any Cargo Airport in China |
By Sea | Any available in China, such as Shanghai and Ningbo |
Новинки товаров от производителей по оптовым ценам