Model | Model | JRA-GR30248 | JRA-GR40296 | JRA-GR50296 | ||||
Rated Power | Rated Power | 3000w | 4000w | 5000w | ||||
Battery Voltage | Battery Voltage | DC 24V/48V | DC 48V/96V | DC 48V/96V | ||||
Net Weight(kg) | Net Weight(kg) | 23 | 28 | 35 | ||||
Parameter | Parameter | |||||||
DC Input | DC Input Voltage Range | DC10V-15V( Single 12V battery standard) | ||||||
Undervoltage Shutdown | DC 8V | |||||||
Low Voltage Protection | DC 10.5V(9.6~12.5V)Adjustable | |||||||
Low Pressure Alarm | DC 11V (9.8~13V) Adjustable | |||||||
High Voltage Protection | DC 17V | |||||||
High Voltage Alarm | DC 15V | |||||||
Battery Priority Opens The High Voltage Point | DC 13.5V (11.5~14.5V) Adjustable | |||||||
Battery Priority Termination Low Voltage Point | DC 10.8V (9.8~14V) Adjustable | |||||||
AC Charging Voltage | DC 13.8V(12~15V) Adjustable | |||||||
AC Charging Current | 0-20A Adjustable | |||||||
AC Input | Input Mode | Single Phase L+N+PE | ||||||
Input Frequency | 50/60Hz+0.5% | |||||||
Input Waveform | Pure Sine Wave | |||||||
Input Voltage | AC 165~265V±5% | |||||||
AC Low-voltage Conversion Battery | AC 165V±5% | |||||||
AC Low Voltage Recovery | AC 175V±5% | |||||||
AC High-voltage Conversion Battery | AC 265V±5% | |||||||
AC High Voltage Recovery | AC 255V±5% | |||||||
AC Output | Output Mode | Single Phase L+N+PE | ||||||
Output Voltage | Stabilized Output AC220V±5% Adjustable | |||||||
Output Frequency | 50/60Hz+0.5% Tracking Automatically | |||||||
Inverted Output Waveform | Pure Sine Wave | |||||||
Inverter Output Efficiency | >90% | |||||||
Mains Output Efficiency | 99% | |||||||
THD | <3%(Resistive Load) | |||||||
Switching Time | <10ms(Typical Loads) | |||||||
Defencive Function | Overload protection,overvoltage protection,undervoltage protection Output short circuit protection,Over temperature protection | |||||||
Customize Battery | Customize Battery | Charge and discharge parameters of different types of batteries can be customized according to user requirements | ||||||
Standby Loss | <1%(Rated power) | |||||||
Working Mode | AC First/ Energy Saving mode/ Battery First | |||||||
Unattended | Manual display setting | |||||||
Display | LCD | |||||||
Thermal Method | Cooling fan in intelligent control(Temperature over 45 dgree,fan runs at high speed) | |||||||
Communication | RS232/4G/WIFI(Optional) | |||||||
Alarm | Battery failure, voltage anomaly, or overload, the buzzer will beep 4 times per second. | |||||||
Environment | Operating Temperature | -15℃~50℃ | ||||||
Storage Temperature | -15℃~60℃ | |||||||
Elevation | ≤1000m(More than derating) | |||||||
Humidity | 10%~90% ( No condensation) |