Сохранить в закладки 1601338126129:
Part Number | 02353DJE-001 |
Model | S5731S-H24T4S-A |
Description | S5731S-H24T4S-A(24*10/100/1000BASE-T ports,4*GE SFP ports,1*150W AC power) |
Chassis material | Metal |
Height [mm] | 43.6 mm |
Depth [mm] | 420.0 mm |
Wide [mm] | 442.0 mm |
Chassis height [U] | 1 |
Weight with packaging [kg(lb)] | 9.35 (20.61) |
Weight without packaging [kg(lb)] | 6.04 (13.32) |
Maximum power consumption [W] | 91 |
Typical power consumption [W] | 70 |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Maximum heat dissipation [BTU/hour] | 310.5 |
Typical heat dissipation [BTU/hour] | 238.85 |
Power supply mode | Pluggable power supply |
Input voltage range [V] | - AC input: 90–290 V AC; 45–65 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC |
Rated input voltage [V] | - AC input: 100 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC |
Maximum input current [A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Number of power slots | 2 |
Number of card slots | 0 |
Memory | 4 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Types of fans | Pluggable |
Noise at normal temperature (acoustic power) [dB(A)] | 57.5 |
Noise at normal temperature (acoustic pressure) [dB(A)] | 47.5 |
Airflow direction | Air intake from front, air exhaustion from rear (front-to-rear) |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
MTBF [year] | 57.73 |
MTTR [hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 28 |
Maximum number of 100GE ports | 0 |
Maximum number of 40GE ports | 0 |
Maximum number of 25GE ports | 0 |
Maximum number of 10GE ports | 0 |
Maximum number of GE ports | 28 |
Maximum number of FE ports | 24 |
1000M optical interface | 4 |
1000M electrical interface | 24 |
USB | Supported |
Console port | RJ45 |
Eth Management port | RJ45 |
Service port surge protection [kV] | Common mode: ±6 kV |
Power supply surge protection | - AC power module configured: ±6 kV in differential mode, ±6 kV in common mode - DC power module configured: ±2 kV in differential mode, ±4 kV in common mode |
RPS input | Not supported |
PoE | Not supported |
Новинки товаров от производителей по оптовым ценам