Selection of correction for the refriferated compressed air dryer
Approve Min Capacity= Inlet flow/(A*B*C*D)
| Air Inlet Temperature Correction Factor | ||||||||
| Air Inlet Temperature | Standard N Type | 25 | 30 | 35 | 40 | 41 | 42 | 45 |
| High Temp H Type | 50 | 55 | 60 | 65 | 70 | 75 | 80 | |
| Correction Factor A | 1.15 | 1.10 | 1.05 | 1.00 | 0.97 | 0.93 | 0.85 | |
| Working Pressure Correction Factor | ||||||||
| Working pressure Mpa | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | |
| Correction Factor B | 0.8 | 0.88 | 0.92 | 1.00 | 1.05 | 1.12 | 1.25 | |
| Ambient Temperature Correction Factor | ||||||||
| ambient temperature | Air cooling | 25 | 30 | 32 | 35 | 38 | 40 | |
| Correction Factor C | 1.20 | 1.12 | 1.10 | 1.05 | 1.00 | 0.90 | ||
| Cooled Water Temp | Water Cooling | 30 | 32 | 34 | ||||
| Correction Factor C | 1.00 | 0.97 | 0.94 | |||||
| Pressure Dew Point Correction Factor | ||||||||
| Dew point requirement | 0 | 2 | 5 | 7 | 10 | |||
| Correction Factor D | 0.90 | 1.00 | 1.10 | 1.15 | 1.20 | |||
Selection of correction for the refriferated compressed air dryer
Approve Min Capacity= Inlet flow/(A*B*C*)
| Air Inlet Temperature Correction Factor | |||||||||
| Air Inlet Temperature | 25 | 30 | 35 | 40 | 45 | 50 | |||
| Correction Factor A | 1.00 | 1.00 | 1.00 | 0.97 | 0.88 | 0.73 | |||
| Working Pressure Correction Factor | |||||||||
| Working pressure Mpa | 0.44 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.2 |
| Correction Factor B | 0.63 | 0.75 | 0.88 | 1.00 | 1.13 | 1.25 | 1.38 | 1.5 | 1.5 |
| Pressure Dew Point Correction Factor | |||||||||
| Dew point requirement | -20 | -40 | -60 | -70 | |||||
| Correction Factor C | 1.10 | 1.00 | 0.85 | 0.7 | |||||
| ZA-1HTA | ZA-2HTA | ZA-3HTA | ZA-6HTA | ZA-8HTA | ZA-10HTA | ZA-13HTA | |
| Capacity (Ncbm/min) | 1.2 | 2.4 | 3.8 | 6.5 | 8.5 | 10.7 | 13.5 |
| Power(V/HZ) | 220/50 | 380/50 | |||||
| Compressor Power (HP/KW) | 1/0.85 | 1/0.85 | 1.25/1.0 | 1.5/1.25 | 1.5/1.25 | 3/2.5 | 3/2.5 |
| Fan Power(W) | 55 | 90 | 150 | 190 | 190 | 2*150 | 2*150 |
| Air inlet size | ZG1 | ZG1 | ZG1.5 | ZG1.5 | ZG1.5 | ZG2 | ZG2 |
| Weight(KG) | 48 | 78 | 105 | 125 | 130 | 180 | 192 |
| Length(MM) | 630 | 700 | 850 | 880 | 880 | 1180 | 1180 |
| Width(MM) | 450 | 450 | 500 | 550 | 550 | 670 | 670 |
| Height(MM) | 640 | 830 | 920 | 1020 | 1120 | 1080 | 1080 |


Airend: BAOSI AIREND, HANBELL AIREND, ROTOCOMP AIREND FOR YOUR CHOOSE.
The Heavy load of low temperature ( 6-8c ) of large oil cooling and air cooler, unique structure design and reasonable lay out, low noise, designed to meet the air, the principle of gas flow, the heat radiating area is greatly increased. The cooling effect is more ourstanding.




Reliable quality of Schneider electric element, to ensure the long-term, without machine avoidance operation, low energy concumption.
Long life filter design, filter large area, small air breath resistance, indeed keep air clean and free of impurities.
Roraty type oil fiter, completely filter out the impurity in the lubricating oil, ensure clean prolong the service life.


1)Pre-sale services:
24 hours' online service for the prompt reply.
2)Sale services:
Our professional engineer team will provide you the satisfied scheme according to your demand.
3)After-sale services:
To offer the better service, we will do the satisfaction survey for each sale experance and regularly pay return visit to customers.

| Packaging | |
| Size | 100(L) *100 (W) *100 (H) |
| Weight | 350KG |
| Packaging Details | we also have other packing for choose: 1. tray. 2. snap-gauge 3. Bubble cotton |





91.8% Response Rate
91.8% Response Rate
91.8% Response Rate
New products from manufacturers at wholesale prices