Item | Details |
Part Number | 98011778 |
Model | S5731-L8T2ST-RUA |
Description | S5731-L8T2ST-RUA (8*10/100/1000BASE-T ports, 1*GE SFP port, 1*10/100/1000BASE-T port, AC power, power adapter) |
Wide [mm] | 210.0 mm | ||||
Depth [mm] | 130.0 mm | ||||
Height [mm] | 27.0 mm | ||||
Chassis height [U] | 0.61 | ||||
Weight with packaging [kg(lb)] | 1.14 (2.51) | ||||
Weight without packaging [kg(lb)] | 0.84 (1.85) | ||||
Typical power consumption [W] | 7.73 W (device) 7.98 W (device + power adapter) | ||||
Maximum power consumption [W] | 7.86 W (device) 8.11 W (device + power adapter) | ||||
Typical heat dissipation [BTU/hour] | 26.38 (device) 27.23 (device + power adapter) | ||||
Maximum heat dissipation [BTU/hour] | 26.82 (device) 27.67 (device +power adapter) | ||||
Heat dissipation mode | Natural heat dissipation | ||||
Power supply mode | Power adapter | ||||
Rated input voltage [V] | Power adapter input: 100–240 V AC; 50/60 Hz Power adapter output: 12 V DC | ||||
Input voltage range [V] | Power adapter input: 90–290 V AC; 47–63 Hz | ||||
Maximum input current [A] | 1 A | ||||
Number of card slots | 0 | ||||
Number of power slots | 0 | ||||
Memory | -- | ||||
Flash memory | -- | ||||
Redundant power supply | Not supported | ||||
Types of fans | None | ||||
Noise at normal temperature (acoustic pressure) [dB(A)] | Noise-free (no fans): < 20 | ||||
Noise at normal temperature (acoustic power) [dB(A)] | Noise-free (no fans): < 30 | ||||
Airflow direction | - | ||||
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) | ||||
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | ||||
Restriction on the operating temperature variation rate | When the altitude is 1800-5000 m (5905.44-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (721.78 ft.). The device cannot start when the temperature is lower than 0°C (32°F). The operating temperature of a device ranges from -5°C to +45°C (23°F to 113°F)) when the device uses the following optical modules: - GE optical modules with a transmission distance of less than or equal to 10 km | ||||
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) | ||||
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) | ||||
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | ||||
MTBF [year] | 84.79 | ||||
MTTR [hour] | 2 | ||||
Availability | >0.99999 | ||||
Maximum number of physical ports on the entire device | 10 | ||||
Maximum number of 100GE ports | 0 | ||||
Maximum number of 40GE ports | 0 | ||||
Maximum number of 25GE ports | 0 | ||||
Maximum number of 10GE ports | 0 | ||||
Maximum number of GE ports | 10 | ||||
Maximum number of FE ports | 9 | ||||
1000M electrical interface | 8 | ||||
1000M optical interface | 1 | ||||
USB | Not supported | ||||
Console port | Not supported | ||||
Eth Management port | Not supported | ||||
Service port surge protection | Common mode: ±6 kV | ||||
Power supply surge protection | Power adapter: ±6 kV in differential mode and ±6 kV in common mode | ||||
RPS input | Not supported | ||||
PoE | Not supported |